24VDC Pneumatic Solenoid Valve 49888035 Techni Water Jet Pump Parts For Sale
24VDC Pneumatic Solenoid Valve 49888035 Techni Water Jet Pump Parts For Sale
The part 49888035 is a 24 VDC solenoid valve, 2-3 way, 2-position, normally-open pneumatic valve used on 60 000 psi Intensifier-Assembly-80072333-Good-Quality-Water-Jet-Parts-In-Stock-p.html target='_blank'>Intensifier pumps in Waterjet systems.
Specifications
Valve Type:2-3 Way, 2-Position, Solenoid, Normally-Open
Voltage:24 VDC
Power Consumption~5.4 W
Operating Medium:Clean, dry compressed air (80–100 psi supply recommended)
Ports:3 pneumatic ports (one inlet, two outlets)
Body Material:Stainless sTeel alloy per OEM standards
Operating Pressure:Rated for pneumatic actuation on 60 000 psi (4 100 bar) hydraulic systems
Installation & Maintenance
Shutdown & Isolate: Power down the waterjet, relieve hydraulic and pneumatic pressures.
Remove Old Valve: Unscrew the solenoid valve from its mounting port on the intensifier manifold.
Inspect & Clean: Verify mating surfaces are free of debris; clean air lines and fittings.
Install New Valve: Thread the new 49888035 valve into the port, hand-tighten, then torque to manufacturer specifications.
Electrical Connection: Wire the 24 VDC solenoid coil per the schematic; ensure secure, polarity-correct connections.
Functional Test: Repressurize air supply, actuate valve electrically, and observe correct dump or control action; check for air leaks.
Specifications
Valve Type:2-3 Way, 2-Position, Solenoid, Normally-Open
Voltage:24 VDC
Power Consumption~5.4 W
Operating Medium:Clean, dry compressed air (80–100 psi supply recommended)
Ports:3 pneumatic ports (one inlet, two outlets)
Body Material:Stainless sTeel alloy per OEM standards
Operating Pressure:Rated for pneumatic actuation on 60 000 psi (4 100 bar) hydraulic systems
Installation & Maintenance
Shutdown & Isolate: Power down the waterjet, relieve hydraulic and pneumatic pressures.
Remove Old Valve: Unscrew the solenoid valve from its mounting port on the intensifier manifold.
Inspect & Clean: Verify mating surfaces are free of debris; clean air lines and fittings.
Install New Valve: Thread the new 49888035 valve into the port, hand-tighten, then torque to manufacturer specifications.
Electrical Connection: Wire the 24 VDC solenoid coil per the schematic; ensure secure, polarity-correct connections.
Functional Test: Repressurize air supply, actuate valve electrically, and observe correct dump or control action; check for air leaks.