Nc UHP Pneumatic Valve Repair Kit 20477521 Pump Replacement Parts
Nc UHP Pneumatic Valve Repair Kit 20477521 Pump Replacement Parts
The part 20477521 is a normally-closed pneumatic valve repair kit for 90 000 psi (6 200 bar) intensifier dump valves, containing all internal seals, backup rings, valve stem, and seat needed to rebuild the on/off valve actuator without a full assembly replacement.
The 20477521 repair kit includes:
Seal Assembly: Top actuator O-ring and seal assembly
Valve Seat: Precision-machined seat for leak-free closure
Valve Stem: Flat-end stainless steel stem (NC type)
Backup Rings: Brass and stainless steel rings to support seals
O-Rings: Two O-rings for stem and piston sealing
Bearing Disk: Ensures smooth piston movement and correct alignment
Specifications
Valve Type:Normally-Closed Pneumatic Dump Valve
Rated Pressure:90 000 psi (6 200 bar)
Actuation Medium:Clean, dry compressed air (80–100 psi)
Seal Materials:O-rings; PTFE backup rings
Valve Stem Material:Stainless steel
Kit Weight:~0.062 lbs (28 g)
Installation & Maintenance
Depressurize: Fully isolate hydraulic and pneumatic supplies; relieve all pressure.
Remove Valve: Unscrew the dump valve from the intensifier manifold; disconnect air lines.
Disassemble: Remove old seals, backup rings, seat, and stem. Inspect bore and components for wear.
Rebuild: Install new kit components in correct sequence: O-rings → backup rings → seat → stem → bearing disk.
Reassemble & Test: Reinstall valve, reconnect air, cycle at low pressure to check for leaks, then ramp to full 90 K psi and verify proper operation
The 20477521 repair kit includes:
Seal Assembly: Top actuator O-ring and seal assembly
Valve Seat: Precision-machined seat for leak-free closure
Valve Stem: Flat-end stainless steel stem (NC type)
Backup Rings: Brass and stainless steel rings to support seals
O-Rings: Two O-rings for stem and piston sealing
Bearing Disk: Ensures smooth piston movement and correct alignment
Specifications
Valve Type:Normally-Closed Pneumatic Dump Valve
Rated Pressure:90 000 psi (6 200 bar)
Actuation Medium:Clean, dry compressed air (80–100 psi)
Seal Materials:O-rings; PTFE backup rings
Valve Stem Material:Stainless steel
Kit Weight:~0.062 lbs (28 g)
Installation & Maintenance
Depressurize: Fully isolate hydraulic and pneumatic supplies; relieve all pressure.
Remove Valve: Unscrew the dump valve from the intensifier manifold; disconnect air lines.
Disassemble: Remove old seals, backup rings, seat, and stem. Inspect bore and components for wear.
Rebuild: Install new kit components in correct sequence: O-rings → backup rings → seat → stem → bearing disk.
Reassemble & Test: Reinstall valve, reconnect air, cycle at low pressure to check for leaks, then ramp to full 90 K psi and verify proper operation