Sealing Head Flat Outlet Poppet Spring 05147863 Good Quality Water Jet Parts
1-11024-High-Pressure-Waterjet-Parts-In-Stock-For-Sale-p.html target='_blank'>Sealing-Head-Flat-Outlet-1-11014-Abrasive-Waterjet-Parts-With-Good-Quality-Supplier-p.html target='_blank'>Poppet-3HAC022379-001-Axis-2-3-For-Robot-Water-Jet-Cutting-Machine-Parts-In-Stock-p.html target='_blank'>Sealing-Head-Flat-Outlet-Poppet-05116561-Water-Jet-Parts-Supplier-p.html target='_blank'>05116561-Water-Jet-Parts-Supplier-p.html target='_blank'>Sealing Head 05116603-Abrasive-Waterjet-Parts-For-Sale-p.html target='_blank'>05116603-Abrasive-Waterjet-Parts-For-Sale-p.html target='_blank'>Flat Outlet Poppet Spring 05147863-Good-Quality-Water-Jet-Parts-p.html target='_blank'>05147863 Good Quality Water Jet Parts
The Sealing Head Flat Outlet Poppet Spring 05147863 is a flared compression spring designed for the flat‑outlet poppet valve in KMT sealing heads, replacing the older straight spring to eliminate wedging issues in the outlet poppet bore. Engineered for use with .875″ plungers under both HP (60 000 psi / 4 100 bar) and UHP (90 000 psi / 6 200 bar) cycles, it ensures reliable valve response and extended component life.
Installation & Maintenance
1. Depressurize & Drain: Fully relieve system pressure and drain water from the Intensifier-Assembly-80072333-Good-Quality-Water-Jet-Parts-In-Stock-p.html target='_blank'>Intensifier.2. Disassemble Sealing Head: Remove the sealing head assembly per KMT service manual instructions.
3. Replace Spring: Extract the old spring, inspect and clean the bore, then press the flared spring 05147863 into the spring guide until fully seated.
4. Reassemble & Test: Reinstall poppet, guide, and head components; repressurize slowly and verify leak‑free poppet function at full HP/UHP pressure.
If you need other KMT Waterjet Parts,Please contact us!