Installation & Maintenance
1. Depressurize & Drain: Fully relieve system pressure and drain the Intensifier Pump.
2. Disassemble Sealing Head: Remove the sealing head assembly per KMT service manual instructions.
3. Remove Old Poppet: Use a suitable puller or light press to extract the worn poppet; inspect the bore for wear or debris.
4. Prepare Bore: Clean and lightly polish the seating bore to ensure a smooth surface for the new poppet.
5. Install New Poppet: Press 05144662 into the bore until fully seated; reassemble the sealing head components.
6. Pressure‑Test: Reassemble and repressurize gradually, verifying leak‑free operation at full pressure.